Technical Support

Design Manuals

The Vista Aluminum Railing System is engineered to meet all major U.S. and Canadian building code requirements. Please refer to Vista’s Design Manual for further details.

View our American Design Manual (Adobe PDF2.5MB PDF)

View our Canadian Design Manual (Adobe PDF5MB PDF)

An Important Note
Recent testing indicates that posts with welded base plates fail at loads an average of 35% lower than identical posts with mechanical base plate connections. The strength of welded post base connections can be deceiving and their use is generally not recommended. Vista aluminum railings utilize a mechanical connection for this critical area, the post/base plate connection. These test results correspond with data published by the CSA and ANSI certification bodies.